IMP PIM SAM
Zone Temperature
Controller
for Runnerless Molding
Applications
Manual
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - IMP PIM SAM

IMP PIM SAM Zone TemperatureController for Runnerless MoldingApplicationsManual

Page 2 - CONTROLS YOU CAN DEPEND ON

Procedure for Manual Control Pre-Set1- Adjust controller for closed-loop operation and obtaingood molded parts. This will adjust the controller to the

Page 3

on, indicating that the remote standby functionis active. b- If the controller is in open-loop mode, the poweroutput is reduced to 1/4 of the value ad

Page 4 - PIM SERIES

3- Thermocouple open or reversed:If any TC fault is detected during closed-loop operation,the output power will be cut off. If it is necessary toapply

Page 5

What to do:A. Try resetting the controller by turning its AC power OFF andthen ON.B. If “No Heat” persists, then the problem could be one of thefollow

Page 6

143- For 120 Vac input operation,install the 2 jumpers on the PC board as shown.4- For 240 Vac input operation,install the 1 jumper on the PC board as

Page 7 - Section III. Operation

OPERATING INSTRUCTIONSModel SAM Communications ModuleSection I. InstallationCAUTIONNever insert or remove the module from a main framewith the AC powe

Page 8

Section II. General SpecificationsStandby Temperature 200 deg F (93 deg C)AC Input Requirements 240 Vac +10% -20%, 48-63 Hz (standard)120 Vac (Availab

Page 9

17QUICK REFERENCE GUIDESPEAKERFAST HIGHER TONE = OVER TEMPERATURE 30°F(17°C) OR MORE ABOVE SETPOINT SLOW LOWER TONE = UNDER TEMPERATURE30°F (17°C) OR

Page 10

Section III. Basic Operation3.1 Select Normal or Standby Mode.3.2 Select Low Temperature Alarm Mode.3.2.1. Low Temperature Alarm Inhibit : Speaker wil

Page 11

4.2 Alarm Indications: When an overtemperature or undertemperature condition exists in any zone occupied by an IMP controller, both audio (tones) and

Page 12

2ATHENA...TEMPERATURE/PROCESS AND POWER CONTROLS YOU CAN DEPEND ON.Since 1965, Athena Controls, Inc. has been atthe forefront of control technology, a

Page 13

4.4 Low Temperature Alarm Mode Switch: This switch gives theoperator the ability to defeat both the low temperature audioalarm, and output connector r

Page 14

NOTES21

Page 15 - OPERATING INSTRUCTIONS

MOLD(FEMALE)CABLE ENDCKPTF1CABLEMPTC10 (10 FOOT)MPTC20 (20 FOOT)(MALE)CABLE ENDCKPTM1MAINFRAME CONNECTORCKPTOC1MOLD CONNECTORCKPTIC1POWER OUTANDTHERMO

Page 16

PIM1A10POWER CORD IN, 5 PIN OUT23AC INPUT OUTPUT

Page 17 - QUICK REFERENCE GUIDE

OPERATING INSTRUCTIONSALARM/MODE DISPLAYDISPLAY ALARM SYMBOLSOVER TEMPERATUREUNDER TEMPERATURETHERMOCOUPLE OPENNO HEATTHERMOCOUPLE REVERSEDDIGITAL SET

Page 18 - Section III. Basic Operation

4PIM SERIESPORTABLE SINGLE ZONE HORIZONTAL CONTROLLERPOWER SWITCHONOFFSTANDBY (WARM) REGIONMODE SELECT TOGGLE SWITCHDISPLAY MODE SYMBOLSOPEN LOOP (MAN

Page 19

OPERATING INSTRUCTIONSIMPSeries 15 and 30 Amp Temperature ControllersPIMSeries 10 and 15 Amp Temperature ControllersSection I. General DescriptionThe

Page 20

The IMP plug-in controller is capable of receiving a standby command from the SAM auxiliary module. When a standby or lowheat command is acknowledged

Page 21

To install a plug-in controller into a mainframe, release the locking device on the lower edge of the unit by pulling the plungergently away from the

Page 22

6- When any of the thermocouple (TC) faults are detected,output power will be cut-off automatically and the temperature display will be blanked out.

Page 23 - 5 PIN OUT

C. Manual Open-Loop Operation1- Position the mode select switch to open-loop (“ ”).2- Turn the AC power on.3- After reset delay, the controller